声测管吧 关注:807贴子:165,189
  • 2回复贴,共1

九江承台冷却管

只看楼主收藏回复

&nbsp;1<span style="line-height:150%;font-family:宋体;font-size:16px;">⑴</span><span style="line-height:150%;font-family:宋体;font-size:16px;">冷却管与其下方的钢筋网片<strong><span style="font-size:24px;">15233770008李俊强0317-3175508</span></strong>和竖向的支撑钢筋绑扎或点焊牢固,冷却管如与墩身钢筋发生干扰可适当调整冷却管位置,如与承台钢筋发生干扰可适当调整钢筋位置。<span></span></span>
<p style="text-indent:32px;">
<span style="line-height:150%;font-family:宋体;font-size:16px;">⑵</span><span style="line-height:150%;font-family:宋体;font-size:16px;">为减少施工期温度应力,在承台内埋设冷却水管,降低混凝土最高温升,同时设置测温孔。冷却管采用具有一定强度的内径为<span>50MM</span>,厚为<span>3MM</span>的铁皮管,两端攻丝,采用短节连接,隔一层生胶带以确保其密封性良好。<span><br />
&nbsp; <span>&nbsp;</span></span></span><span style="line-height:150%;font-family:宋体;font-size:16px;">⑶</span><span style="line-height:150%;font-family:宋体;font-size:16px;"> </span><span style="line-height:150%;font-family:宋体;font-size:16px;">冷却管分两层设置,要求位置准确,安放稳固,<span><a href="http://wiki.zhulong.com/baike/detail.asp?t=接头" target="_blank"><span style="color:windowtext;text-decoration:none;"><span>接头</span></span></a></span>连接牢靠。每层冷却管进出水口均需引至承台顶以上<span>50CM</span>,当冷却管与钢筋相碰时,冷却管可适当调整位置。注意每层与钢筋牢固绑扎,管道畅通,丝口<span><a href="http://wiki.zhulong.com/baike/detail.asp?t=接头" target="_blank"><span style="color:windowtext;text-decoration:none;"><span>接头</span></span></a></span>牢靠,并通过通水试验,防止砼在浇注过程中出现冷却管漏水或堵塞现象;<span><br />
&nbsp;&nbsp;</span></span><span style="line-height:150%;font-family:宋体;font-size:16px;">⑷</span><span style="line-height:150%;font-family:宋体;font-size:16px;">设置冷却管的该层混凝土自浇注开始,冷却管内须立即通入冷水,连续通水<span>6</span>天,流量应为<span>1.2m3/h</span>;<span><br />
&nbsp; <span>&nbsp;</span></span></span><span style="line-height:150%;font-family:宋体;font-size:16px;">⑸</span><span style="line-height:150%;font-family:宋体;font-size:16px;"> </span><span style="line-height:150%;font-family:宋体;font-size:16px;">通水过程中对管道流量,进出水温度及混凝土内部温度均需隔<span>1</span>~<span>2</span>小时进行一次测量记录;<span><br />
&nbsp; <span>&nbsp;</span></span></span><span style="line-height:150%;font-family:宋体;font-size:16px;">⑹</span><span style="line-height:150%;font-family:宋体;font-size:16px;">派专人测量混凝土温度,及时采取措施,控制混凝土表面温度与内部温度的差值小于<span>20°C</span>,以确保混凝土质量。经监理认可后,将冷却管<span><a href="http://wiki.zhulong.com/baike/detail.asp?t=灌浆" target="_blank"><span style="color:windowtext;text-decoration:none;"><span>灌浆</span></span></a></span>封孔,并将伸出承台顶面的管道截除。<span></span></span>